A methane barrier is a permeable soil vapor membrane that lies beneath building slabs and retaining walls. Its objective is to prevent subterranean methane soil gas from entering buildings. The ultimate purpose is to safeguard the people who live in buildings near methane soil gas pockets. Petroleum fields, landfills, and any other sort of contaminated plume are examples. Any methane mitigation system must include a methane membrane. While it can occasionally be used for both waterproofing and moisture penetration. The impermeable membrane is made of unique materials that do not allow most volatile organic compounds (VOCs) or hydrocarbons to pass through.
A methane barrier is generally required in regions where methane soil gas is visible as a result of previous oil fields or landfills. For example, the Los Angeles Department of Public Works maintains a map showing methane zones and buffer zones. Buildings in these zones are normally required to have a methane mitigation system. Without a methane barrier, the toxic gas accumulates within, causing an explosion, asphyxiation, and health concerns. Finally, the methane mitigation technique prevents subterranean hydrocarbon gases from entering buildings. And the methane barrier is the system's most important component. In reality, the methane gas is blocked by the specific construction material. Whereas the remainder components divert it from the building space.
The quick answer is that a barrier is typically required in every methane mitigation system, but not always. Methane barrier materials are subject to exceptions and substitutes. The kind of development and the regional building code will determine this, though. According to the Los Angeles Methane Mitigation Standards, for example, certain modest projects with low-level methane testing results may be able to use a thick layer of Visqueen in place of the methane impermeable material.
In methane hazard zones, methane mitigation construction is a critical step in the land development process. Building a mitigation system involves several stages. Usually, the construction of the barrier begins after the footing has been poured. Yet, it is also crucial that it take place prior to laying the last construction slab. An official deputy inspector who has no connection to the methane mitigation contractor must supervise the installation of the methane barrier in order for it to comply with all building department rules and inspections. A thickness test and a leak test must also be performed. And before the last slab is poured, the deputy inspector must monitor this operation.
There isn't much maintenance required after the concrete slab is finished and the methane barrier is in place. Nevertheless, any excavation, trenching, coring, or saw-cutting might result in a leak in the system. The membrane lies underground, thus property owners and their contractors must constantly keep this in mind. Also, professionals must go back to the site to properly seal it if a new permeation is required due to future building. New conduits or piping won't, therefore, turn into a point of methane soil gas infiltration.